Data Center

Overview

· Polcom Data Center is located near Cracow (Poland), in a secured part of the building that is externally protected
· Over 2000 m2 of raised floor Data Center area
· Purpose designed Tier 3+ facility
· Designed in consideration of new generation blade server and data storage technologies
· Scalable, redundant power and cooling capacity up to 15kW per rack
· Factory-new infrastructure as well as current guarantees and service agreements from
suppliers (aggregate, UPS, air-conditioning, fire-fighting system, access control)
· Wide range of services offered – from server collocation to the entire outsourcing of
equipment and administrative service delivery
· SLA (Service Level Agreement) parameters guaranteeing a high level of quality
· Additional services are available through the outsourcing model, including IT equipment servicing and the transfer of administrative duties.


Site Location

· Placed in Skawina – 1 km from highway (ringway of Cracow), 10 km from Balice Airport
· Situated in a safe location not susceptible to natural disasters e.g. flood
· Street position limits possible vehicle rams


Building Capabilities

· Combined building capabilities provides Tier 3+ with a design nominal 99.999% availability
· Capable of modular fit-out and installation of additional UPS, chillers and cooling units without tenant interruption as power and cooling loads increase
· Data Center area is divided into 6 separate rooms
· 2500kg/m2 raised-floor loading capacity across all data center floors
· Secure loading dock with vehicle trap
· Secure Facility Room for unpacking and assembling equipment prior to locating in clean, secure Data Center areas
· Site management workshop for onsite building support and maintenance staff


Power System

· Diverse underground 15kV feeders from bulk supply sub-station
· N+1 redundant standby diesel emergency power
· 2N redundant power supply paths (via transformers, switchboards, UPS, PDU) to each rack
· Ability to provide scalable, redundant power up to 15kW per rack


Cooling System

· N+1 air-conditioning units per data center room
· N+1 redundant chillers
· Dual redundant piping systems to all equipment
· Ability to provide scalable, redundant cooling infrastructure up to 15kW per rack


Fire Protection system

· Very early smoke detection system in the building
· 2N gas fire protection system


Security

· Defence level intruder resistant building
· 24x7x365 onsite manned security
· Separate security access control zones
· Video surveillance to all entries, external, lift lobbies, and Data Center rooms with digital storage and 24/7 monitoring


Other systems

· Leak detection under piping system
· Tele-information infrastructure, with connections to various telecommunications operators

 More details